OPTIBAR DP 7060
with orifice meter run assembly

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For small line sizes
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi; (line pressure)
  • Sizes: DN15…100 / ¾…2"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA
  • Icon/Logo for Total 3D linearisation
  • Icon/Logo Security Integrity Level 2/3 (SIL 2/3)

OPTIBAR DP 7060 with orifice meter run assembly

OPTIBAR DP 7060 with orifice meter run assembly

The calibrated orifice plate meter run with OPTIBAR DP 7060 is a DP flowmeter for volume flow measurement of liquids, gases and steam. It features an inlet and outlet section to guarantee low-disturbance flow measurement. The DP flowmeter is wet-calibrated and designed for use in small line sizes up to DN50 / 2” where the impact of certain parameters such as flow profile, surface property or roughness of the pipe walls is particularly strong. In this way, it meets the demands for higher accuracy DP flow measurement even in applications with small diameter piping.

Due to its broad selection of orifice plate materials and designs (standardised acc. to ISO 5167), the device is suitable for various process conditions and parameters - from high pressure and high temperature media to extremely aggressive fluids. It is also a cost-effective yet reliable device for natural gas or wet gas measurements. The transmitter's very quick response time of just 125 ms allows high accuracy and measurement stability. The meter run is supplied completely assembled and ready for installation, with flange or weld-in connection. It can be provided with temperature and absolute pressure sensors for temperature compensation and is also available with manifolds, valves, condensate pots or other accessories.

Product highlights

  • Supplied completely assembled and ready for installation
  • Standardised acc. to ISO 5167 (for pipes >DN50 / 2") or ISO TR15377 (for pipes <DN50 / 2")
  • With inlet and outlet section for low-disturbance flow measurement
  • All measurement uncertainties under operational conditions are known and can be calculated
  • Optional temperature and pressure compensation
  • Unique 3D linearisation of transmitter: compensation for all influencing factors at virtually all possible combinations
  • With flange or weld in connection
  • Numerous versions with different types of orifice plates or nozzles available
  • Large choice of wetted materials for corrosive and non-corrosive media

Typical applications

General

  • DP flow measurement in applications with small pipe diameters (<DN50 / 2")
  • All sorts of flow measurements in liquid, gas or steam applications of various industries
  • Low pressure (LP), intermediate pressure (IP) and high pressure (HP) measurements in power stations
  • Natural gas measurements
  • Wet gas measurements

Related products

OPTICHECK Pressure Mobile

Mobile app for pressure transmitters

  • Works with all OPTIBAR PM 5060, OPTIBAR PC 5060 and OPTIBAR DP 7060 equipped with Bluetooth display and adjustment module
  • Wireless device commissioning, verification and monitoring even in hard-to-reach areas
  • Parameterisation similar to PACTware DTM including remote SIL mode activation
  • Free download for iOS and Android

View product details

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

View product details

OPTIBAR MR 4300

Orifice meter run assembly with corner taps and annular chambers

  • Completely pre-assembled with orifice plate, piping, inlet/outlet sections, process connections
  • Size: DN15…100 / ½…4"; up to PN100 / ASME Cl 1500
  • Temperature: max. +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 1100

Orifice plate with RF sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5, 16.47 A)
  • Size: ½…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 3100

Orifice plate with flat sealing face and corner taps

  • Separate type, with carrier ring and optional shut-off valve
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 3200

Orifice plate with flat sealing face and corner taps

  • Compact type, with carrier ring, flange plate and optional manifold
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 4100

Orifice plate with annular chamber and corner taps

  • Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 5110

Orifice assembly with measuring flanges (ASME 16.36)

  • With RTJ sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

Links

OPTIBAR portfolio

Related website

Explore our OPTIBAR product portfolio of process instruments for pressure and differential pressure applications.

View website (external link)