OPTIBAR DP 7060
with orifice plate

DP flowmeter for volume flow measurement of liquids, gases and steam

  • For basic to very demanding aggressive, abrasive or viscous media
  • Up to +400°C / +752°F; max. 160 bar / 2320.1 psi (line pressure)
  • Flange: DN50…600 / 2…24"
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA
  • Icon/Logo for Total 3D linearisation
  • Icon/Logo Security Integrity Level 2/3 (SIL 2/3)

OPTIBAR DP 7060 with orifice plate

OPTIBAR DP 7060 with orifice plate

The combination of an orifice plate with the differential pressure transmitter OPTIBAR DP 7060 forms a versatile DP flowmeter for a wide range of applications with liquids, gases or steam. Due to its broad selection of orifice plate materials and designs the flowmeter is suitable for various process conditions and parameters - from high pressure and high temperature media to extremely aggressive fluids. It is also a cost-effective yet reliable device for natural gas or wet gas measurements. The differential pressure flowmeter covers a wide diameter range and can be provided wet-calibrated for increased accuracy. It comes with various digital communication options.

Product highlights

  • Worldwide standardised flow measurement principle according to ISO 5167
  • One pressure transmitter for all flow applications: compact or remote version
  • Change of pressure transmitter without process interruption
  • Integrated absolute pressure measurement
  • All measurement uncertainties under operational conditions are known and can be calculated
  • Optional temperature and pressure compensation
  • Optimisation of measuring points according to a given specification, e.g. short inlet/outlet sections, low pressure loss, small overall uncertainty, etc.
  • No moving parts
  • Unique 3D linearisation of transmitter: compensation for all influencing factors at virtually all possible combinations
  • Use in hazardous areas
  • Various orifice plate designs available
  • Large choice of wetted materials for corrosive and non-corrosive media
  • SIL 2/3

Typical applications

General

  • All sorts of flow measurements in liquid, gas or steam applications of various industries
  • Low pressure (LP), intermediate pressure (IP) and high pressure (HP) measurements in power stations
  • Natural gas measurements
  • Wet gas measurements

Applications

Related products

OPTICHECK Pressure Mobile

Mobile app for pressure transmitters

  • Works with all OPTIBAR PM 5060, OPTIBAR PC 5060 and OPTIBAR DP 7060 equipped with Bluetooth display and adjustment module
  • Wireless device commissioning, verification and monitoring even in hard-to-reach areas
  • Parameterisation similar to PACTware DTM including remote SIL mode activation
  • Free download for iOS and Android

View product details

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

View product details

OPTIBAR OP 1100

Orifice plate with RF sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5, 16.47 A)
  • Size: ½…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 1110

Orifice plate with RTJ sealing face

  • For mounting between measuring flanges (ASME 16.36, 16.5)
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +450°C / +842°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 3100

Orifice plate with flat sealing face and corner taps

  • Separate type, with carrier ring and optional shut-off valve
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 3200

Orifice plate with flat sealing face and corner taps

  • Compact type, with carrier ring, flange plate and optional manifold
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 4100

Orifice plate with annular chamber and corner taps

  • Separate type, for installation between standard flanges (EN 1092-1), optional shut-off valves
  • Size: DN50…600; up to PN100
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 5100

Orifice assembly with measuring flanges (ASME 16.36)

  • With RF sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

OPTIBAR OP 5110

Orifice assembly with measuring flanges (ASME 16.36)

  • With RTJ sealing face and flange taps
  • Size: 1…24"; up to ASME Cl 2500
  • Temperature: up to +400°C / +752°F
  • Material: 1.4404 / 316L

View product details

Links

OPTIBAR portfolio

Related website

Explore our OPTIBAR product portfolio of process instruments for pressure and differential pressure applications.